Modified Sine Wave TS Series

TS seriesFeatures

  • SELF TEST:
    Self test each time switched on.
    When UPS is turned on, it makes self-test to provide a reliable operation and prevent any damage  caused.

    BATTERY PROTECTION:
    Auto self-test and discharge protection.

  • DC START CAPABILITY:
    The UPS can be activated without utility power.


  • UPS POWER SUPPLIED OUTLETS:
    Line-Interactive UPS+AVR Allowes 75% to 125% input voltage range-best protection for computer equipment.
    With AVR function (boost & buck), UPS provides a stable power to the loads as the input voltage fluctuates.

  • ELECTRICAL PROTECTION:
    Automatic cut off on short circuit or Input Circuit Breaker. If UPS is overload, this circuit breaker will trip
    to disconnect the unit from utility power.
    Then the black button will pop up, and none of the surge protection outlets will provide power.
    Unplug at least one piece of equipment, and reset the circuit breaker by pressing the button back into place.

  • MODEM/NETWORK PROTECTION:
    RJ45 JACK; Simultaneous protection for network, telephone, fax & modem.

  • AUDIBLE ALARM:
    Battery Back-up: slow beeping (10 seconds)
    Battery Low & overload or AC overload: rapid beeping (1 second)

  • INTERFACE AND SOFTWARE:
    USB Interface. Software for MS-Windows 98/NT/ME/2000
    RS-232 Interface.
    Software for MS-Windows 98/NT/ME/2000, Novell, Linux

  • CPU MICRO PROCESS CONTROL, USE WITH STABILITY.

  • GREEN FUNCTION:
    If the battery is discharging under no load, will shut down automatically to keep the span life of the battery.

  • BATT FAULT: Red LED Display.

TS Series Specification    

 Model  TS-500 TS-650 TS-800
 UPS Voltage / Watts 500VA / 250W 650VA / 325W 800VA / 400W
 Surge Protection Watts 750W 675W 600W
 Input Volts Range (On Line) 110V (80V~140V) / 220V (160V~280V)
 Input Frequence        50 or 60 ± 3Hz
 (AVR) Output Volts Range  110V Out: 100V - 120V        220V Out: 200V - 240V 
 Output Volts On Battery 110VAC ±10%      /     220VAC ±10%
 Output Frequence On Battery 50 or 60 ± 1Hz
 Battery Run Time 10~30 MIN3
 Battery QTY / Rating 2 x 6V4.5AH 1 x 12V7AH 1 x 12V9AH
 Typical Battery Charge Rated 4 hours to 90% of full capacity
 Battery Protection Auto Self-test and discharge protection
 Self Test Self-test each time switched on
 Transfer Time 2~4 ms
 Outlets NEMA Type 8 outlets (4 for surge protection, 4 for battery backup)
Schuko Type 5 outlets (2 for surge protection, 3 for battery backup)
French Type 5 outlets (2 for surge protection, 3 for battery backup)
Australian Type 5 outlets (2 for surge protection, 3 for battery backup)
Universal Type 5 outlets (2 for surge protection, 3 for battery backup)
UK Type 4 UK + 1 IEC (2UK for surge protection, 2UK + 1IEC for battery backup)
 Audible Alarm Battery backup: Slow beeping (10 seconds)
Battery low or overload: Rapid beeping (1 second)
 Indicators Green LED online: Backup slash
Red LED Overload: Battery Fail
 Interface RS-232
 Environment Ambient Operating: 0-40C, 0-95% Humidity non-condensing.
Storage: 15C~45C
 Audible Noise <40 DBA (1 meter from surface)
 DC Start Yes
 Surge Envegy Rating 240 joules
 Overload Backup mode 100%
In AC mode 110% alarms (no shut down)
 Electrical Protection Automatic cut off on short circuit and input circuit fuse
 Modem / Network Protection RJ45 (8 Wire) One in ---> One out operation for modem or network
 Conformance Applicable
 Software (Support) Download from website
 Dimension (mm) L x W x H 270 x 84 x 190
 Net Weight 5.0 KG 5.5 KG 6.9 KG

Login

contact us

10, El Mosheer Ahmed Ismail Str., Sidi Gaber
Alexandria,
Egypt

Call Us: +203 541.0172

Delivery Outside Alexandria

  • For delivery outside Alexandria,
         Please contact: 011 111 13029.